Skip to Content

Icare IC333 Homecare Bed

The IC333 is iCare's premium four-function electric homecare bed — ultra-low at 22 cm, configurable up to 66 cm, with 12,000 N of dual lift power, unlimited under-bed clearance and a choice of six designer fabric colours. Built to order in Melbourne for the Australian home and care environment.

  • Bed Size
  • Bed Frame Fabric
  • iCare Upholstery Colour
Add to wishlist
Price
$ 3,915.00 $ 3,915.00

Terms and Conditions of purchase.

Funding Options

NDIS — National Disability Insurance Scheme Level 3 Funding Code05_181210811_0103_1_2
More info
Level 3 Capital Supports — Specialised
Subsidy: Level 3
Prescription required — AT Specialist / Assessor
Adjustable beds are named as a Level 3 example — AT Specialist assessment and trial recommended.
Support at Home — Australian Government Support at Home Program Medium Tier Funding CodeISO 18 12 10 High Tier Funding CodeISO 18 12 10
More info
Medium Tier AT-HM Medium Tier
High Tier AT-HM High Tier
Prescription required — Occupational Therapist (OT)
SWEP — Statewide Equipment Program (Victoria) VA&EP
More info
VA&EP Aids & Equipment Program
Prescription required — Occupational Therapist (OT), Physiotherapist, Speech Pathologist
Beds, mattresses and patient handling are explicitly covered under SWEP.
DVA — Department of Veterans' Affairs Gold Card White Card
More info
Gold Card Gold Card — Full Coverage
Prescription required — Occupational Therapist (OT), General Practitioner / Medical Specialist
White Card White Card — Accepted Condition Only
Prescription required — Occupational Therapist (OT), General Practitioner / Medical Specialist
TCP — Transition Care Program — short-term post-hospital care (usually loaned AT) TCP Loan
More info
TCP Loan Short-Term Loan AT
Prescription required — Allied Health Team
Home care beds are commonly supplied as short-term loan equipment after hospital discharge.
Loading…
iCare IC333 Homecare Bed — Product Page
iCare Medical Group Made in Melbourne NDIS Eligible

IC333 Homecare Bed

Hospital-grade function. Home-worthy design.

The IC333 is iCare's premium four-function electric homecare bed — ultra-low at 22 cm, configurable up to 66 cm, with 12,000 N of dual lift power, unlimited under-bed clearance and a choice of six designer fabric colours. Built to order in Melbourne for the Australian home and care environment.

  • 200 kg Capacity
  • 22–66 cm Height Range
  • 4 Electric Functions
  • Trendelenburg
  • 8 Heavy-Duty Castors
  • 10 Year Frame Warranty
  • ARTG Registered
iCare IC333 Homecare Bed with CurveX and accessories
Height (Min)
22 cm
Height (Max)
66 cm
Head Lift Angle
62°
Knee Break Angle
42°
Safe Working Load
200 kg (Single/KS)
Lift Power
12,000 N (4× motors)
Castors
8 × heavy-duty swivel
Frame Warranty
10 years limited
ARTG
233386
Origin
Made in Melbourne
Four-Function Electric

Complete Positioning Control

Four independent electric functions give caregivers and users precise, safe control over every aspect of positioning — all from a single backlit handpiece.

1
Head Lift

Raises the backrest up to 62° for sitting up comfortably to eat, read or watch TV.

2
Knee Break

Bends the knees up to 42° to improve circulation, prevent sliding and add comfort.

3
Hi–Lo Height

Raises or lowers the entire bed platform (22–66 cm) for safe transfers and carer back care.

4
Trendelenburg

Tilts the full bed platform for pressure injury prevention and circulation management.

IC333 at ultra-low height

Ultra-Low — 22 cm from Floor

The IC333's minimum height of just 22 cm from floor to mattress platform dramatically reduces fall risk for residents prone to rolling or attempting to exit the bed unsupervised. It also lowers the distance of any unassisted transfer, reducing injury severity.

Unlimited under-bed clearance means hoists, wheelchairs and lifting equipment slide underneath without obstruction — reducing physical strain on carers during repositioning.

Falls Prevention Hoist Clearance Carer Back Care

Full Height Range — 22 cm to 66 cm

Adjust the deck height instantly for any care scenario, from safe low-fall positions to carer-comfortable working heights.
22 cm
Minimum Height
Floor to top of mattress platform. Ultra-low for fall prevention and safe overnight positioning.
66 cm
Maximum Height
Raises the bed to a carer-ergonomic working height, reducing stooping and back strain during personal care.
Clinical Positioning

Trendelenburg & Anti-Trendelenburg

The IC333 offers full Trendelenburg (feet elevated) and reverse Trendelenburg (head elevated) positioning — an evidence-based clinical tool for shifting pressure points without repositioning the patient manually.

Used regularly and incrementally, Trendelenburg tilt prevents pressure injuries by redistributing weight away from bony prominences. It also supports circulation management, post-surgical recovery and respiratory positioning.

  • Shifts pressure away from sacrum and heels without manual repositioning
  • Supports lower-limb oedema management and venous return
  • Assists lung drainage and respiratory positioning
  • Reduces need for frequent manual turns by carers
  • Ideal for complex care, post-surgical, and palliative settings
IC333 Queen bed
IC333 backlit handpiece and controls

Backlit Handpiece — Simple, Safe Control

The wired handpiece features large, clearly labelled buttons for each function. The backlight illuminates automatically for night use, allowing residents to safely adjust their position in the dark without calling for assistance.

The wired stretch cord keeps the handpiece within reach at all times, and a hook attachment lets it hang securely from the bed rail when not in use. The surface is fully wipeable for hygiene compliance.

Backlit for Night Use Wired Stretch Cord Wipeable Surface Rail Hook Included
IC333 CurveX corner detail and breathable platform

Strong Breathable Mattress Platform

The IC333's deck uses a heavy-gauge metal mesh surface beneath the mattress, allowing significantly increased airflow compared to solid platform bases. This improves mattress performance, extends mattress life, and is especially important for pressure care mattresses that rely on airflow to function correctly.

End and corner mattress retainer bars are included as standard, preventing the mattress from shifting during position changes — an important safety feature for residents in the Hi position.

Increased Airflow Mattress Retainer Bars Compatible with All ActiveX Mattresses

Available Sizes

All sizes share the same four-function specification. Safe working load increases to 300 kg on Double and Queen.
LS
Long Single
Mattress surface: 2030 × 910 mm · SWL: 200 kg
KS
King Single
Mattress surface: 2030 × 1070 mm · SWL: 200 kg
DB
Double
Mattress surface: 2030 × 1370 mm · SWL: 300 kg
QN
Queen / Split Queen
Mattress surface: 2030 × 1500 mm · SWL: 300 kg · Split option available

Fabric & Vinyl Colour Options

Choose from seven premium fabric colours or five antibacterial vinyl finishes to match your room. Fabric samples available on request.
Fabric
Silver fabric
Silver
Fabric
Stone fabric
Stone
Fabric
Smoke fabric
Smoke
Fabric
Onyx fabric
Onyx
Fabric
Mist fabric
Mist
Premium Fabric
Royal fabric
Royal
Premium Fabric
Noir fabric
Noir
Premium Fabric
Vinyl
Ebony vinyl
Ebony
Vinyl
Dove vinyl
Dove
Vinyl
Sand vinyl
Sand
Premium Vinyl
Bison vinyl
Bison
Premium Vinyl
Slate vinyl
Slate
Premium Vinyl

Optional Accessories

Expand the IC333 with accessories to meet complex clinical and safety requirements.
🛡️
High Side Rails

Full-length high rails for residents at risk of falls. Lateral positioning mounts allow placement anywhere along the bed.

🔧
Low Side Rails

Shorter profile rails for lower-risk residents or for use with the bed in the lowest position.

🔋
Battery Backup

External rechargeable battery ensures uninterrupted bed operation during power outages — essential for 24/7 care.

🪟
Headboards & Footboards

Available in matching fabric finishes to complete the bedroom aesthetic and create a furniture-grade appearance.

🧲
U-Assist Rail

Assists residents in pulling themselves to a sitting position independently, supporting self-care and dignity.

📐
Over-Bed Pole

Provides a grab point directly above the bed for independent transfers and repositioning.

Everything the IC333 Includes as Standard

No add-on packages — these are all built into every IC333.
Head Lift (62°) Knee Break (42°) Hi–Lo Height Adjust Trendelenburg & Reverse Ultra-Low 22 cm Unlimited Under-Bed Clearance 8 Heavy-Duty Castors Lockable Corner Castors Backlit Wipeable Handpiece Stretch Cord + Rail Hook Breathable Metal Mesh Deck Mattress Retainer Bars No-Pull Motors (Safety) 6 Colour Options Partner Bed Compatible ARTG Registered

Detailed Specifications

Measurements in millimetres unless stated. Mattress and headboard not included.
SpecificationLong SingleKing SingleDoubleQueen
Dimensions
Mattress Surface (L × W)2030 × 9102030 × 10702030 × 13702030 × 1500
Base Size (L × W)2450 × 10002450 × 11552450 × 14602450 × 1580
Min Height (floor to platform)220 mm (22 cm)
Max Height (floor to platform)660 mm (66 cm)
Positioning Range
Head Lift Angle0° – 62°
Knee Break Angle0° – 42°
TrendelenburgYes (both directions)
Capacity & Motors
Safe Working Load200 kg200 kg300 kg300 kg
Head Adjust Actuator1 × 6,000 N / 24 W
Knee Adjust Actuator1 × 6,000 N / 24 W
Height Adjust Actuators2 × 6,000 N / 24 W2 × 8,000 N / 24 W
Total Lift Power12,000 N16,000 N
Compliance
ARTG Registration233386
StandardAS|NZS IEC 60601.1:2015 · IEC 60601-2-52
NDIS Item Code (Power Bed)05_181210201_0103_1_2
NDIS Item Code (Composite)05_423_0103_1_2

NDIS & Home Care Package Funding

The IC333 is registered with the ARTG and carries NDIS item codes for both powered bed and composite claim types. It is prescribable under NDIS Assistive Technology and Home Care Package (HCP) Level 3–4 supports. An occupational therapist assessment and functional assessment is typically required. Our team can provide quotes, specification documentation and product trials to support your funding application.

05_181210201_0103_1_2 05_423_0103_1_2 ARTG 233386

Warranty & Compliance

10 yr
Steel Frame
2 yr
Actuators
2 yr
Control Box
2 yr
Castors & Handpiece
2 yr
Fabric & Surround
Warranty Coverage & Claims
iCare Medical Group warrants the IC333 against defective materials and workmanship from the date of invoice, for the periods listed above. All warranty claims must be directed to your place of purchase (your Assistive Team consultant will liaise with iCare directly). If the bed needs to return to the factory for assessment, freight is covered by the distributor and reimbursed by iCare if a covered fault is confirmed. Damage caused by misuse, overloading beyond rated SWL, or unauthorised modifications voids all warranty.
Usage & Safe Operating Guidelines
Do not exceed the rated safe working load for your size (200 kg Long Single/King Single; 300 kg Double/Queen). The SWL includes the weight of the mattress. Always ensure castors are locked before positioning or transferring a resident. Do not drag the bed by the power cord. Ensure the area under the bed is clear before lowering from Hi position. If operating near or over electrical cord: inspect for wear regularly. The bed should only be operated by persons who have been trained in its use.
Cleaning & Infection Control
Wipe the frame, rails and surround with a damp cloth and mild hospital-grade detergent. The handpiece is wipeable — do not submerge. Vinyl surrounds (Dove and Ebony) are antibacterial and waterproof — suitable for TGA-compliant disinfection. Fabric surrounds (Silver, Stone, Smoke, Onyx) should be spot-cleaned with mild detergent. Avoid abrasive cleaners or bleach on painted surfaces. Inspect castors and lock mechanisms at each resident review.
Battery Backup Operation
If the optional rechargeable battery backup is fitted, it will engage automatically on power failure, allowing the bed to be repositioned to a safe height before the power is restored. The battery is not designed for continuous use during extended outages — it provides enough reserve for emergency repositioning. Recharge the battery fully between uses and inspect the charge indicator periodically.
Partner Bed Configuration
The IC333 is available in Split Queen configuration, where two Long Single or King Single bases sit side by side with zero gap between the mattress surfaces. This allows couples with differing care needs to share a bed — each with independent position controls. To set up a partner configuration, each side is prescribed and quoted separately. iCare provides a Partner Beds Script Form to assist OTs in specifying the correct combination. Contact us for a partner bed assessment.